Filters

Vapour Control Layers

View
Novia VC4000 FR Reflective Vapour Control Layer - 1.5m x 50mNovia VC4000 FR Reflective Vapour Control Layer - 1.5m x 50m
Novia VC200 Reflective Vapour Control Layer - 2.7 x 100mNovia VC200 Reflective Vapour Control Layer - 2.7 x 100m
Novia VC200 Reflective Vapour Control Layer - 1.5 x 50mNovia VC200 Reflective Vapour Control Layer - 1.5 x 50m
Novia VC2 Air Tight Vapour Control Layer - 1.5m x 50mNovia VC2 Air Tight Vapour Control Layer - 1.5m x 50m
Novia VariCheck FR AVCL (1.5m x 50m)Novia VariCheck FR AVCL (1.5m x 50m)
Novia Radon Barrier 1600 Gauge - 4m x 20m Roll

Vapour Control Layer FAQs

What is a Vapour Control Layer (VCL) and why is it important?
A Vapour Control Layer (VCL) is a membrane used in construction to manage moisture movement within a building. It prevents condensation build-up inside insulation, reducing the risk of dampness, mould, and deterioration of structural elements.

Where should a Vapour Control Layer be installed?
VCLs should always be installed on the warm side of the insulation, typically on the interior-facing side of walls, ceilings, and floors. This placement helps to stop warm, moisture-laden air from reaching the cooler insulation, preventing condensation formation.

What happens if a Vapour Control Layer is not used?
Without a VCL, moisture from inside the building can penetrate insulation and structural components, leading to mould growth, weakened insulation performance, and potential long-term damage to the structure. Over time, this can compromise the building’s energy efficiency and durability.

How does a Vapour Control Layer improve energy efficiency?
By preventing moisture from penetrating insulation, a VCL ensures that insulation retains its full thermal efficiency. Even a small amount of moisture can significantly reduce insulation performance, leading to higher energy costs and reduced indoor comfort.

Are all Vapour Control Layers the same?
No, VCLs vary in terms of thickness, material composition, and performance ratings. Some, like the Novia VC4000 FR, are fire-rated for high-rise buildings, while others, such as Novia Reflex, include reflective properties to enhance thermal insulation. Choosing the right VCL depends on the specific requirements of your project.

Can a Vapour Control Layer be used in a high-rise building?
Yes, but only fire-rated VCLs, such as the Novia VC4000 FR, should be used in high-rise buildings. These membranes comply with fire safety regulations while still offering excellent moisture control and airtightness.

Do Vapour Control Layers need to be taped and sealed?
Yes, for maximum airtightness and moisture protection, VCLs must be properly sealed using Novia butyl and foil tapes. Overlapping the layers and securing them with strong adhesive ensures no moisture can bypass the barrier, maintaining long-term effectiveness.

What is the difference between a Vapour Control Layer and a breather membrane?
A VCL is installed on the warm side of insulation to stop moisture from entering the building fabric, whereas a breather membrane is installed on the cold/external side to allow moisture vapour to escape while preventing rain and external contaminants from getting in. Both work together to create an efficient moisture management system.

Can a Vapour Control Layer be installed in a retrofit project?
Yes, VCLs can be installed in both new builds and retrofit projects. They are particularly useful in renovation projects where existing insulation may not have adequate moisture protection. Proper sealing and installation are essential to achieving the best results.

How quickly can Vapour Control Layers be delivered?
We offer fast UK delivery within 1-2 working days, ensuring your project stays on schedule. Simply place your order, and we’ll get your Vapour Control Layer to you as soon as possible.

 

Recently viewed